Device Readings

Team
Utilities Team
Last Updated
September 11, 2026

Device Readings - Energy

The Device Readings report brings energy readings aggregated per device and per period, ready for periodic analysis and reporting.

Some columns are optional and only appear depending on your account's configuration — if a column listed below isn't present in your file, it isn't enabled for your organization.

The file name follows the pattern events.<window end date and time>.<extension>, for example: events.2024-05-24T17:00:00.000Z.csv.gz

Columns

ColumnDescription
org_idOrganization identifier
device_idDevice identifier
channelDevice channel (only present for accounts with multi-channel devices)
remote_idDevice's remote identifier
event_timeReading date and time
energy_directAccumulated direct (consumed) energy
energy_reverseAccumulated reverse (injected) energy
edge_timeDevice communication date and time
latency_min / latency_maxCommunication latency range
countNumber of raw records aggregated into this row
alarmsList of alarms active during the period
count_distinct_usersNumber of distinct users in the period (optional)
users_android / users_ios / users_stationsUsers by source in the period (optional)
energy_direct_rawRaw direct energy reading, before conversion (optional)
pulse_factorMultiplier factor used in the reading calculation (optional)
device_offset / result_offsetOffsets used in the reading calculation (optional)

Unlike the water/gas integration, energy alarms are not sent in a separate file: they come in the alarms column of this same file.

Example

org_iddevice_idremote_idevent_timeenergy_directenergy_reverseedge_timelatency_minlatency_maxcountalarms
412884210EN-0023112024-05-24 13:00:00+0015230.400000.000002024-05-24 13:02:05+0038964[]
412884210EN-0023112024-05-24 14:00:00+0015231.850000.000002024-05-24 14:01:47+0041884[]
412884210EN-0023112024-05-24 15:00:00+0015233.100000.000002024-05-24 15:02:12+00391044[]
412884211EN-0023122024-05-24 15:00:00+008420.5500012.300002024-05-24 15:01:58+00441104[]
412884212EN-0023132024-05-24 15:00:00+0022105.750000.000002024-05-24 15:03:21+00471313[LOW_BATTERY]

How to set it up

This report is available in the Format step of the BATCH integration creation, under the name Leituras dos Dispositivos.

Technical Support

If you have any questions or technical issues during the process, our technical support team is available. You can reach us by email at [email protected] or via WhatsApp at (11) 91162-6684.